Troubleshooting Informatica Error Messages and Resolution – Part 97

CMN_1807Cache version does not match with <version>.
Cause:You enabled recovery for a session. The session failed during the session run. Before you started the recovery session, the cache folder was modified. This is not allowed.
Action:When a session configured for recovery fails, make sure that the cache file is not modified before starting the recovery session.

CMN_1808Cache platform does not match with <platform>.
Cause:You enabled recovery for a session. The session failed during the session run. Before you started the recovery session, the recovery cache was moved to a different platform. For example, you ran a session on Windows to read messages from a TIBCO source. After the session failed, the recovery cache was moved to a UNIX platform. You tried to run the session in recovery mode on UNIX. This is not allowed.
Action:Run sessions in recovery mode on the same platform as the initial session.
CMN_1809Partition number does not match with <number>.
Cause:You enabled recovery for a session. The session failed during the session run. Before you started the recovery session, the number of partitions for the session changed. This is not allowed.
Action:When a session configured for recovery fails, make sure that the number of partitions does not change before starting the recovery session.

CMN_1836Error: Data for Lookup fetched from the file is not sorted on the condition ports.
Cause:You ran a flat file lookup session configured for sorted input, but the data for the condition columns is not grouped.
Action:Clear the sorted input option in the Lookup transformation.
or
Action:Ensure that data in the condition columns are grouped.
CMN_1919External loader error. Error getting Teradata loader information.
Cause:The Integration Service could not fetch information from the repository to build the Teradata control file.
Action:Verify the Integration Service machine can connect to the Repository Service machine and that the Repository Service machine can connect to the repository. Verify the repository machine is plugged in and connected to the network
CMN_1920External loader error. Error getting Flat-File information required for Loader.
Same as CMN_1919.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Informatica Error Code Messages or Warning Messages on Windows and Linux Operating Systems.

 