WRT_8215External loader error. The external loader process <process ID> exited prematurely.
Cause:This error is related to WRT_8216. The external loader exited unexpectedly during the session because the named pipe broke and the session failed.
Action:Check the external loader log file for details.
WRT_8216External loader error. Broken Pipe.
Cause:The Integration Service could not write data to the named pipe because the external loader exited unexpectedly during a session. The external loader may exit if it runs out of disk space.
Action:Check the external loader log file for details, and verify that there is sufficient disk space.

WRT_8218Error: Teradata external loader requires a primary key on table <table name> when using load mode <load mode>.
Cause:You did not set a primary key on the table when using load mode update, upsert, or delete.
Action:Set a primary key on the target table.
WRT_8219Error: Table mismatch, target table <table name> with <number of columns> columns mismatch with physical table with <number of columns> columns.
Cause:The number of columns in the target table is different than the physical table.
Action:In the Designer, recreate the table or reload the target table from the database.
WRT_8220Error: get deadlock when reading /writing database.
Cause:Database error.
Action:Contact your database administrator.

WRT_8226 Target Load Order Group <TLOG> is set for real-time flushing. Target based commit is switched to source based commit and target based commit interval is used as source based commit interval.
Cause:This is an informational message. You configured the session for real-time data extraction with target-based commits. The Integration Service will run the session with source-based commits.
Action:If you want to run the session in real time, you do not need to take any action.
Action:If you want to run the session with target-based commits, remove the flush latency function from the filter condition.
WRT_8229Database errors occurred: <database error message>.
Cause:The Integration Service encountered an error from the database.
Action:Refer to the Informatica Knowledge Base.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

SQLServerF1 Team
Information about Informatica Error Code Messages or Warning Messages on Windows and Linux Operating Systems.


Leave a Reply

Your email address will not be published. Required fields are marked *