VAR_27079Warning: <variable type>: [variable name], NULL override value not valid. The override value is set to empty string.
Cause:You set a mapping variable to NULL in the parameter file, but the variable cannot have a null value. The Integration Service reset the variable value to an empty string.
Action:Check the value of the variable in the parameter file. Set it to a value other than NULL.

VAR_27082The line <line> specified in the parameter file is too long and the line will be truncated at [value] characters.
Cause:A single line in a parameter file must be 1024 characters or fewer. If the line declares the value for a string variable, the string may be too long.
Action:Rewrite the line so that it contains no more than 1024 characters.
VAR_27086Cannot find specified parameter file <file name> for <workflow/session name>.
Cause:The Integration Service cannot find the parameter file.
Action:Verify that the parameter file exists in the location specified in the pmcmd command line, workflow properties, or session properties. Verify that the parameter file name is spelled correctly.

VAR_27097Error: Failed to read line from parameter file <file name> for <workflow/session name>.
Cause:The Integration Service cannot read the parameter file.
Action:Verify that the user configured to start Informatica Services has read permission on the parameter file directory. Verify that the parameter file is valid.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Informatica Error Code Messages or Warning Messages on Windows and Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *