Troubleshooting Informatica Error Messages and Resolution – Part 4


Mapping representing this profile is not valid. This profile cannot be run in interactive mode.
Cause:The mapping is invalid because it has been modified.
6 Chapter 1: Client Error Messages
Action:Regenerate the profile mapping.
Action:If this is the first time that you generated the mapping, and you did not modify it, contact Informatica Technical Support.
No Integration Service is registered in the repository to run this profile.
Cause:An Integration Service is not configured to run against the data profiling repository.
Action:Configure an Integration Service for the data profiling repository.

No report is available for the profile .
Cause:The Integration Service has not generated a report for the selected data profile because a profile session has not been run for the data profile or the data profile has been edited.
Action:You must run a profile session before you can view a report.
No session log was created for this session.
Cause:The session failed.
Action:Check the workflow log or the Event Viewer for a message that indicates the reason for the failure. Correct the error and rerun the session.

None of the columns from source can be used in Intersource Structure Analysis.
Cause:The Intersource Structure Analysis function included a source with no columns that meet the defined values for allowed precision.
Action:Edit the data profile to remove this source.
Action:Adjust the precision definitions to bring this source within the allowable range.
Not connected to the warehouse.
Cause:An incorrect ODBC database connection was specified for viewing reports.
Action:Enter the correct ODBC database connection in the Profile Manager. Make sure that the target warehouse connection for viewing reports matches the relational database connection you specified when you ran the profile session.
Referential Integrity Analysis is not valid for groups in the same source.
Cause:More than one group from the same source was specified while adding or editing an Referential Integrity Analysis function.
Action:Move groups back to the Available Sources field, leaving one group from each source in the Selected Sources field.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.