TM_6765Error: Cannot run the grid-enabled session <session> in Debugger.
Cause:You cannot run grid-enabled sessions in debug mode.
Action:Disable Session on Grid and run the session again.
or
Action:Debug the mapping.

TM_6772Worker DTM running partition group <partition group ID>, failed to connect to the Master DTM at <host name and port number of master DTM process> with timeout <timeout value> seconds.
Cause:The worker DTM was unable to connect with the master DTM in the specified timeout period. The master DTM process may have shut down unexpectedly, or there may be a network failure.
Action:Check with the Network Administrator to verify that the network does not have connectivity issues. Check with the Domain Administrator to verify that the Integration Service is running.
TM_6775Failed to update the session status with master service process with error msg <error message text> and error code <error code>.
Cause:The master DTM process was unable to connect with the master service process to update the session status. The master DTM process may have shut down unexpectedly, or there may be a network failure.
Action:Same as TM_6772.

TM_6777Temporary profiling sessions cannot be grid-enabled.
Cause:You attempted to run a temporary profile session on an Integration Service running on a grid.
Action:Create a persistent profile session, or run the temporary profile session on an Integration Service that is not assigned to a grid.
TM_6788Error: Unable to open temporary log file <log file name> with error <error code>. Session log will not be attached to post session e-mail.
Cause:The Integration Service attempted to create a log file in the PowerCenter Services Installation directory but was unable to access the directory to create the file. The Integration Service could not attach the session log to the post-session email because it could not create the file in the specified directory.
Action:Verify that the PowerCenter Services user has write permissions for the PowerCenter Services installation directory to ensure the Integration Service can create a temporary log file.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.