TIB_38007 TIBCO writer rejected the row because of the overflow error for field <field>.
Cause:Row error. Data overflow occurred in the specified field.
Action:Use a larger datatype for the output field. For example, use int64 instead of int32.
TIB_38008Data was truncated for field <field>.
Cause:This is a warning message. The data for a string field was truncated.
Action:Increase the precision of the output field.

TIB_38009 TIBCO writer failed to get error threshold value.
Cause:Internal error. The repository may contain inconsistencies.
Action:Contact Informatica Technical Support.
TIB_38010 SendSubject field cannot be connected when pre-registered listeners are specified for the writer.
Cause:The session properties contain pre-registered listeners for a TIBCO target. Also, the mapping contains a link to the SendSubject port in the target definition. This is not allowed.
Action:Remove the link to the SendSubject port in the target definition to use the default subject during the session. Remove the pre-registered listeners you specified in the session properties.

TIB_38012The target instance contains the datatype msg, which is incompatible with a TIB/Adapter SDK connection.
Cause:A field in the target definition contains the datatype msg. This datatype is incompatible with the TIB/Adapter SDK application connection. As a result, the session failed.
Action:Remove any fields in the source definition with the datatype msg. To include the message metadata in this field, add the metadata as separate columns in the target definition.
TIB_38013Target instance contains the header field Time Limit, which is incompatible with a TIB/Adapter SDK connection.
Cause:You attempted to run a session with a TIB/Adapter SDK application connection for a TIBCO target. However, the TIBCO target definition contains the port Time Limit, which is linked with the Time Limit port in another transformation. As a result, the session failed.
Action:Remove the link to the Time Limit port in the target definition.TIB_38014Target instance contains the datatype ipaddr32 or ipport16, which is incompatible with a TIB/Adapter SDK connection.
Cause:You selected a TIB/Adapter SDK application connection for a TIBCO target. However, the TIBCO target definition contains fields with the datatypes ipaddr32 and/or ipport16. This is not allowed.
Action:Use the datatype string for fields with ipaddr32 or ipport16 datatypes.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.