Application source qualifier has business component and other sources.
Cause:The listed application source qualifier is connected to a Siebel business component source definition and other source definitions. You cannot join a Siebel business component with other Siebel sources.
Action:Use a separate application source qualifier for each Siebel source definition.

Application source qualifier has filter clause which uses one or more fields that were not selected.
Cause:The listed application source qualifier has a filter clause which uses one or more fields that you did not select from the business component.
Action:In the filter clause, only use the fields that you select from the business component.
Application source qualifier has join override clause which uses one or more fields that were not selected.
Cause:The listed application source qualifier has a join override clause which uses one or more fields that you did not select from the business component.
Action:In the join override clause, only use the fields that you select from the business component.

Application source qualifier has more than one business component attached.
Cause:The listed application source qualifier is associated or connected to more than one Siebel business component source definition. You can associate or connect one business component source definition to a single application source qualifier.
Action:Disconnect one of the business component source definitions from the application source qualifier or remove one of the associated business component source definitions from the mapping.
or
Action:To use more than one business component in a single mapping, create an application source qualifier for each business component you want to use. Use a Joiner transformation to join two related business components.
Application source qualifier has one or more calculated fields projected out. NULL data would be produced for such fields. Generate a mapplet for this business component before using calculated fields.
Cause:An application source qualifier contains one or more fields with calculated expressions connected to a target or another transformation. You cannotconnect Siebel business component fields with calculated expressions from an application source qualifier to a target or another transformation.
Action:Disconnect any ports that connect fields with calculated expressions from the application source qualifier to the target or transformation. Generate a Siebel business component mapplet to interpret the calculated expressions in the business component. Connect the fields with calculated expressions from the application source qualifier to the Siebel business component mapplet.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.