Troubleshooting Informatica Error Messages and Resolution – Part 361

TIB_34022 Failed to confirm certified message: <TIBCO error message>.
Cause:The Integration Service could not confirm the specified certified message.
Action:Consult the TIBCO documentation for instructions to correct the error.
TIB_34023 Invalid IP address <IP address>. Should be either unsigned integer or in the format of a.b.c.d, where a, b, c and d range from 0-255.
Cause:The IP address for the column is invalid. The datatype for the column should be uint. The value of the column should be in the format of a.b.c.d, where a, b, c, and d range from 0-255. For example, 300.300.300.300 is an invalid value for the column, whereas 127.0.0.1 is a valid value for the column.
Action:Verify that the data contains the correct value for IP address.

TIB_34024 Invalid IP port <port>. Should range from <nunber>-<number>.
Cause:The port for the column is invalid. The value should range from 1 to 65,535.
Action:Verify that the data contains the correct value for the port.
TIB_34025 Incompatible datatype for field <field>.
Cause:Some connected ports in the mapping have datatypes that are not compatible with the message data fields.
Action:Modify the mapping to include datatypes that are compatible.
TIB_34026 Data overflow happened when trying to insert value <value> into field of type <datatype>.
Cause:The Integration Service could not pass all the data from one column to another. The specified value is too large for the column with the specified datatype.
Action:Modify the datatype for the column in the mapping.

TIB_34027 Invalid date.
Cause:The date value for the column is invalid.
Action:Check the data. Make sure the data contains valid values for the date.
TIB_34028 Data overflow.
Cause:The Integration Service could not pass all the data from one column to another. The precision of the output port might be larger than the precision of the input port. For example, the datatype of the output port is int64 and the datatype of the input port is int8. The precision of the output port is higher than the precision of the input port. As a result, the data might contain inconsistencies. The row was rejected.
Action:Modify the mapping by changing the precision or datatypes of the ports so that the precision of the output port is greater than or equal to the precision of the output port.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Informatica Error Code Messages or Warning Messages on Windows and Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *