Troubleshooting Informatica Error Messages and Resolution – Part 357

SQLServerF1

TE_7114Error: Guaranteed Message Delivery does not allow a dynamic lookup cache in the mapping.
Cause:The session contains a dynamic lookup cache. When you enable message recovery for a session, you cannot use a dynamic lookup cache in the mapping.
Action:Use a static lookup cache in a mapping for the session.
or
Action:Do not use message recovery for the session. To remove message recovery for the session, clear the Enable Recovery option in the session properties.

TE_7115Error: The source configured for Guaranteed Message Delivery cannot be a Joiner transformation master source.
Cause:The session contains a mapping with a JMS source that is a Joiner master source. When you enable message recovery for the session, the source cannot be the Joiner master source.
Action:Do not use message recovery for the session. To remove message recovery for the session, clear the Enable Recovery option in the session properties.
TE_7116Error: Guaranteed Message Delivery does not allow partition types other than pass-through for each partitioning point.
Cause:You enabled message recovery and selected a partition type other than pass-through for a partition point.
Action:When you enable message recovery, you must select pass-through partitioning at all partition points in the session properties.
or
Action:Do not use message recovery for the session. To remove message recovery for the session, clear the Enable Recovery option in the session properties.

TE_7117 Error: RealTime commit does not allow non-realtime SDK targets in the mapping.
Cause:You configured a session using Real-time Flush Latency as a session condition. However, the mapping contains an SDK target definition that you cannot use with real-time sessions.
Action:Enter 0 for the Real-time Flush Latency session condition.
TE_7122Error: Session is running in UDC mode; however, the target [target name] is not receiving transactions from any upstream transformations.
Cause:You ran a user-defined commit session, but you did not connect the specified target to an upstream effective transaction generator.
Action:Connect an effective transaction generator, such as a Transaction Control transformation, to the target.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Informatica Error Code Messages or Warning Messages on Windows and Linux Operating Systems.

 

Leave a Reply