SM_7207Incremental aggregation upgrade error.
Cause:The Integration Service failed to upgrade the incremental aggregation files.
Action:See additional error messages for more information.
SM_7208Mapping has been modified since the incremental aggregation files for transformation <transformation name> were last saved.
Cause:The Integration Service failed to upgrade the incremental aggregation files because you modified a mapping containing an Aggregator transformation or modified the Aggregator transformation. Then, when you ran the incremental aggregation session, the Integration Service tried to reuse the existing cache file that was invalid with the Aggregator modifications.
Action:To reuse the data in the cache, revert to the last version of the mapping. Otherwise, delete the existing incremental aggregation files or configure the session to reinitialize the aggregate cache.

SM_7209Cache for transformation <transformation name> was created in a precision mode different from the one specified by the session.
Cause:The Integration Service failed to upgrade the incremental aggregation files because the Enable High Precision session option used for the incremental aggregation files differs from the option used for the current session.
Action:If the Enable High Precision session option was changed in error, change the option back to its original setting. Otherwise, delete the existing incremental aggregation files or configure the session to reinitialize the aggregate cache.
SM_7210Number of partitions has changed since cache creation.
Cause:The Integration Service failed to upgrade the incremental aggregation files because you changed the number of partitions in the session.
Action:To reuse the data in the cache, change the number of partitions back to the original value. Otherwise, delete the existing incremental aggregation files or configure the session to reinitialize the aggregate cache.

SM_7211The Integration Service data movement mode differs from the data movement mode used when the cache was created.
Cause:The Integration Service failed to upgrade the incremental aggregation files because you started a session using incremental aggregation after changing the Integration Service data movement mode. The Integration Service cannot access incremental aggregation files created in a different data movement mode.
Action:If the Integration Service data movement mode was changed in error, change the data movement mode back to its original setting. Otherwise, delete the existing incremental aggregation files or configure the session to reinitialize the aggregate cache.

SM_7217Error: Failed to expand update override for target instance .
Cause:The Integration Service cannot expand a parameter or variable in the target update override.
Action:Verify that the parameter or variable is defined properly in the parameter file and that its value in the parameter file matches the parameter or variable datatype. For example, you cannot set an integer mapping variable to a text string in the parameter file.
or
Cause:The Integration Service cannot expand the parameter or variable in the target update override due to an internal error.
Action:Contact Informatica Technical Support.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

Thanks,
SQLServerF1 Team