SF_34120Cannot persist request GUID <GUID>, made by client application <client name> on host <host name> through connection <connection name>. Request might not be executed following a service process failure.
Cause:During a transient failure, the Integration Service could not access the $PMStorageDir to store the request for recovery.
Action:Verify that the Integration Service can access $PMStorageDir. If the directory does not exist or cannot be written to, the request cannot be persisted.
SF_34130Cannot get the storage files in directory <directory name>.
Cause:The storage directory does not exist or there are no storage files in this directory.
Action:Make sure the $PMStorageDir directory path is set to directory that exists, and you have proper write permissions to the directory.

SF_34132Errors encountered while reading from storage files.
Cause:You do not have write permission, or the disk is full.
Action:Make sure you have write permission, and the disk has enough room for the storage file.
SF_34134Error in writing to storage file <file name>.
Cause:You do not have write permission, or the disk is full.
Action:Make sure you have write permission, and the disk has enough room for the storage file.
SF_34135Errors encountered while writing to storage files.
Cause:The Integration Service does not have write permission on the directory to write the state of operations.
Action:Verify that the user configured to start Informatica Services has write permission, and the disk has enough room for the storage file.
SF_34136Error in removing storage file <file name>.
Cause:The storage file is in use, or you do not have write permissions on the storage file.
Action:Make sure you have write permission, and the disk has enough room for the storage file.

SF_34155Child process [process ID] terminated due to spurious abort errno [error number].
Cause:The Session or Command task exited unexpectedly and the machine running the Integration Service process generated an error.
Action:Use the error number to determine the cause of the error. If it indicates an out-of-memory error, increase the swap space or reduce the maximum processes threshold. You define the maximum processes threshold on the Properties tab for the node in the Administration Console.
Review the core file of the process for the Command task.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Informatica Error Code Messages or Warning Messages on Windows and Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *