REP_32214Warning: invalid key name <KEYRANGE or HASHKEY name> for element <element name>.
Cause:In the XML file, you specified a NAME attribute in a KEYRANGE or HASHKEY element that references a non-existent transformation port.
Action:Edit the XML file, and enter a valid NAME. Or, export the object again and then import it.

REP_32215Error: Invalid DSQ type <DSQINSTTYPE> for element <SESSIONEXTENSION name>.
Cause:In the XML file, you specified an invalid DSQINSTTYPE attribute for the SESSIONEXTENSION element.
Action:Edit the XML file, and specify a valid DSQINSTTYPE attribute. Or, export the object again and then import it.
REP_32216Error: connection reference <CONNECTIONREFERENCE name> type <TYPE> and subtype <SUBTYPE> is not valid for the extension.
Cause:In the XML file, you specified CONNECTIONTYPE and CONNECTIONSUBTYPE attributes in the specified CONNECTIONREFERENCE element that are not valid for the TYPE and SUBTYPE attributes of the SESSIONEXTENSION element.
Action:Edit the XML file, and verify the type and subtypes of the CONNECTIONREFERENCE and SESSIONEXTENSION elements are compatible. Or, export the object again and then import it.

REP_32217Error: a partition name <PARTITIONNAME> is given for a non-partitionable connection reference for session transformation instance <session transformation instance name>.
Cause:In the XML file, you included a PARTITIONNAME attribute in a CONNECTIONREFERENCE element that is not partitionable.
Action:Edit the XML file, and remove the PARTITIONNAME attribute from the CONNECTIONREFERENCE element. Or, export the object again and then import it.
REP_32218Error: Invalid task type <task type> for element <element name>.
Cause:In the XML file, you specified an invalid TYPE attribute in the TASK element.
Action:Edit the XML file, and enter a valid TYPE for the TASK. Or, export the object again and then import it.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Informatica Error Code Messages or Warning Messages on Windows and Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *