REP_12736The database <database name> and Integration Service <Integration Service name> do not have compatible code pages.
Cause:Validation error. The session contains a Lookup or Stored Procedure transformation and the code page for the lookup or stored procedure database is not compatible with the Integration Service code page. This causes the session to fail when the Integration Service runs in the Unicode data movement mode.
Action:If the Integration Service runs in ASCII mode, you can ignore this warning. If the Integration Service runs in Unicode mode, correct the problem with one of the following actions:
−Choose a different Integration Service to run the workflow.
−Correct the configured code page for the database in the Workflow Manager.
−Choose a different lookup or stored procedure database in the session properties.
−Correct the code page registered for the Integration Service.
REP_12773The Global Repository code page (<code page name>) is not compatible with the selected code page (<code page name>).
Cause:While upgrading a local repository, the local repository code page must be a superset of the global repository code page.
Action:Choose an appropriate code page.

REP_12782The repository <repository name>’s code page <code page name> and <PowerCenter Client>’s code page <code page name> are incompatible.
Cause:The PowerCenter Client code page is not compatible with the code page of the repository to which you are trying to connect. The PowerCenter Client and repository code pages must be compatible. Their code pages must also be compatible with the Integration Service code page.
Action:Change the code page for the PowerCenter Client to one that is compatible with the repository code page. Or, if you need to change the repository code page, you can copy the repository to a new location or backup and restore it. Both actions allow you to configure a different code page for the repository.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.