Troubleshooting Informatica Error Messages and Resolution – Part 281

SQLServerF1

REP_12654Password is too long.
Cause:You entered a password that exceeded the limit of 76 characters.
Action:Use a shorter password.
REP_12678The connection to Global DataMart Repository is unavailable for some reason.
Cause:The global repository connection failed while trying to fetch a shortcut. The connection information for the global repository might have changed or the repository database server is down.
Action:Check the database error message for more information and correct the problem. Update connection information in the administration console if it has changed.
REP_12708Unable to allocate memory.
Cause:The Integration Service machine is out of memory.
Action:Increase virtual memory or close other applications.

REP_12709Unable to find database type for this source.
Cause:Internal error.
Action:Contact Informatica Technical Support.
REP_12734The source database <source database connection> and Integration Service <Integration Service name> do not have compatible code pages (one way compatibility is required).
Cause:Validation error. The code page of the source database connection is not a subset of the Integration Service code page. This causes the session to fail when the Integration Service runs in the Unicode data movement mode.
Action:If the Integration Service runs in ASCII mode, you can ignore this warning. If the Integration Service runs in Unicode mode, correct the problem with one of the following actions:
−Choose a different source database connection for the session.
−Choose a different Integration Service to run the workflow.
−Correct the code page configured for the source database connection.
−Correct the code page registered for the Integration Service.

REP_12735The source file <file name> and Integration Service <Integration Service name> do not have compatible code pages. (One way compatibility is required.)
Cause:Validation error. The code page of the source file is not a subset of the Integration Service code page. This causes the session to fail when the Integration Service runs in the Unicode data movement mode.
Action:If the Integration Service runs in ASCII mode, you can ignore this warning. If the Integration Service runs in Unicode mode, correct the problem with one of the following actions:
−Choose a different source file and code page for the session.
−Choose a different Integration Service to run the workflow.
−Correct the code page registered for the Integration Service.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Informatica Error Code Messages or Warning Messages on Windows and Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *