Troubleshooting Informatica Error Messages and Resolution – Part 264

PR_18011Application Source Qualifier <Application Source Qualifier name> has projected port with no inbound link.
Cause:The listed Application Source Qualifier has a connected output port, and the corresponding input port is not connected.
Action:Connect the necessary input port, or disconnect the connected output port.
PR_18012SQL Error <SQL statement>.
Cause:Internal error. The Integration Service encountered an error in the listed SQL statement.
Action:Contact Informatica Technical Support.

PR_18013Warning: Application Source Qualifier transformation <Application Source Qualifier name> has a larger number of sorted ports than projected output ports.
Cause:In an Application Source Qualifier, the number of sorted ports option on the Properties tab has a higher value than the number of connected output ports.
Action:Either lower the Number of Sorted Ports value or increase the number of connected output ports in the Application Source Qualifier.
PR_18020The language table <language table name>, for the base table <base table name>, does not have rows for the language <language code>.
Cause:The application connection for the session specifies a PeopleSoft language code, and the source table listed in the error message does not have related data for the language you specified. When there is no data for the specified language, the Integration Service returns data from the base source table.
Action:If you require data in the specified language, that data must be entered into the PeopleSoft system. If you want data in a different language, you can edit the application connection or create a new connection for a different language code.

PR_18021The Application Source Qualifier <Application Source Qualifier> has invalid user defined query <query> with character error at <number> location.
Cause:You entered a query containing characters that are not valid in the source application connection code page.
Action:Edit the query so all characters are valid in the source database connection code page.
PR_18022The Application Source Qualifier <Application Source Qualifier> has invalid filter clause <filter> with character error at <number> location.
Cause:You entered a filter condition containing characters that are not valid in the application connection code page.
Action:Edit the filter condition so all characters are valid in the application connection code page.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Informatica Error Code Messages or Warning Messages on Windows and Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *