PCSF_46007No gateway connectivity is provided for domain [<domain name>].
Cause:The domains.infa file does not contain the information necessary to connect to the domain or the domains.infa does not exist.
Action:Ping the domain using infacmd ping and provide the gateway address. If the connection is invalid, infacmd ping adds or updates domains.infa. If the domain is not running, ask the domain administrator to start Informatica Services.
Action:If you attempted to connect to a repository with the PowerCenter Client, remove the repository in the Navigator and add the repository again.

PCSF_46008Failed to look up service.
Cause:The Service Manager on the gateway is not running, and cannot accept the request.
Action:Use the infacmd ping to verify that the domain is running and the connection parameters are configured correctly. If the domain is running, infacmd displays the host name and port number of the domain. If the domain is stopped or unavailable, ask the domain administrator to start Informatica Services. Contact Informatica Technical Support if the domain is running and you continue to receive an error.
PCSF_46009Invalid type <object type> encountered. Failed to create an object instance.
Same as PCSF_46002
PCSF_46010Cannot parse message: <reason for error>
Cause:You specified the incorrect domain name, gateway host name, or port number from a PowerCenter client application, such as pmcmd or the Designer.
Action:Verify that you use the correct gateway information. If the gateway information is correct, and you continue to receive this error, contact Informatica Technical Support.
or
Cause:The Domain Service could not parse the SOAP message received from a remote client, such as an FTP server.
Action:Review the log for related messages to find out more information.
or
Action:Contact Informatica Technical Support.

PCSF_46012Cannot write to file <file name>.
Same as PCSF_10020.
PCSF_46013Cannot connect to URL < URL > to perform operation <operation name> of service <service name>.
Same as PCSF_10304.
PCSF_46014Cannot connect to gateway to look up service <service>.
Same as PCSF_10305.
PCSF_46015An unexpected token was encountered during deserialization.
Same as PCSF_10095.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Informatica Error Code Messages or Warning Messages on Windows and Linux Operating Systems.

 