OPT_63219 Transformation <transformation> uses pass-through partitioning which is disallowed by dynamic partitioning.
Cause:You cannot enable dynamic partitioning for a relational source using a pass-through partition type. The session runs in one partition by default.
Action:Disable dynamic partitioning or use a database partition type.

OPT_63220Transformation <transformation name> specifies user defined SQL that will not be partitioned.
Cause:You enabled dynamic partitioning for a session with a transformation that has user-defined SQL. The session runs in one partition by default.
Action:Disable dynamic partitioning or remove the user-defined SQL.
OPT_63221The Source Qualifier transformation <transformation name> will not be partitioned because one or more transformations upstream from the Source Qualifier transformation cannot be partitioned.
Cause:The number of partitions must be consistent across a pipeline in a mapping. If the Integration Service cannot dynamically partition a transformation in a pipeline, it does not partition the pipeline. The session runs in one partition by default.
Action:Disable dynamic partitioning.
OPT_63222 Transformation <transformation name> will not be partitioned because dynamic partitioning of SDK readers is not supported.
Cause:You enabled dynamic partitioning in a session containing an SDK source. You cannot enable dynamic partitioning for SDK and PowerCenter Connect sources and targets. The session runs in one partition by default.
Action:Disable dynamic partitioning.

OPT_63223Transformation <transformation name> will not be partitioned because dynamic partitioning of SDK writers is not supported.
Cause:You enabled dynamic partitioning in a session containing an SDK target. You cannot enable dynamic partitioning for SDK and PowerCenter Connect sources and targets. The session runs in one partition by default.
Action:Disable dynamic partitioning.
OPT_63224 Transformation <transformation name> will not be partitioned because dynamic partitioning of XML readers is not supported.
Cause:You enabled dynamic partitioning for a pipeline that contains an XML source transformation. The session runs in one partition by default.
Action:Disable dynamic partitioning.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Informatica Error Code Messages or Warning Messages on Windows and Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *