Troubleshooting Informatica Error Messages and Resolution – Part 234

SQLServerF1

OPT_63078Pushdown optimization to the source stops at the repartition point because an upstream Aggregator transformation is not properly partitioned on the aggregate key.
Cause:You configured a group by port for the upstream Aggregator transformation that is different from the partition key specified for the key-range partition. The group by port and partition key must match.
Action:Configure the group by port and partition key to match.

OPT_63079Pushdown optimization to the source stops at the repartition point because an upstream Sorter transformation is not properly partitioned on the distinct sort key.
Cause:You configured a sort key for the upstream Sorter transformation that is different from the partition key specified for the key-range partition. The sort key and partition key must match.
Action:Configure the sort key and partition key to match.
OPT_63080Pushdown optimization to the source stops at the repartition point because an upstream Joiner transformation is not properly partitioned on the join key.
Cause:You configured a join condition for the upstream Joiner transformation that is different from the partition key specified for the key-range partition. The join condition and partition key must match.
Action:Configure the join condition and the partition key to match.

OPT_63081Pushdown optimization to the source stops at the repartition point because a downstream Aggregator transformation is not properly partitioned on the aggregate key.
Cause:You configured a group by port for the downstream Aggregator transformation that is different from the partition key specified for the key-range partition. The group by port and partition key must match.
Action:Configure the group by port and partition key to match.
OPT_63082Pushdown optimization to the source stops at the repartition point because a downstream Sorter transformation is not properly partitioned on the distinct sort key.
Cause:You configured a sort key for the upstream Sorter transformation that is different from the partition key specified for the key-range partition. The sort key and partition key must match.
Action:Configure the sort key and partition key to match.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.