Troubleshooting Informatica Error Messages and Resolution – Part 212

SQLServerF1

LMTGT_17809Identifier port is not connected in the mapping. The port must be connected when using the Wait for Commit option.
Cause:The Identifier port in the LMAPI target is not connected. However, the Wait for Commit option is selected in the session properties.
Action:Connect the Identifier port in the mapping when you select Wait for Commit in the session properties.

LMTGT_17810Could not find workflow details for key <key name>.
Cause:The LMAPI target received data for a key which does not exist on the Scheduling Information tab of the LMAPI target properties.
Action:Enter a key in the Scheduling Information tab for each value that the LMAPI target will receive in the UKey port.
LMTGT_17811Indicator Table <table name> not found in the mapping.
Cause:The mapping containing the LMAPI target does not include the indicator table. However, an indicator table name is specified on the Scheduling Information tab of the LMAPI target properties.
Action:Verify that the table entered for the Indicator Table field exists in the mapping. The table must contain the fields UKey, Identifier, and Status.
LMTGT_17812Indicator Table name is not specified in the mapping. Indicator Table name is required when using the Wait for Commit option.
Cause:The Indicator Table field on the Scheduling Information tab of the LMAPI target properties does not contain a value. However, the Wait for Commit option is selected in the session properties.
Action:Enter the name of the indicator table in the Indicator Table field when you select Wait for Commit in the session properties.

LMTGT_17818The Integration Service cannot fetch workflow <workflow name> for key <key name>.
Cause:The Integration Service cannot start the workflow because it does not exist or because it does not have a unique name in the repository.
Action:Verify that all workflows scheduled in the LMAPI target exist in the repository and have unique names in the repository.
LMTGT_17820Warning: Lost server connection.
Cause:The LMAPI target lost its connection to the Integration Service.
Action:Verify that the Integration Service is running.
LMTGT_17821Error communicating with Integration Service.
Cause:The LMAPI target failed to communicate with the Integration Service.
Action:Verify that the Integration Service is running.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Informatica Error Code Messages or Warning Messages on Windows and Linux Operating Systems.

 