LM_36385Workflow <name>: Could not acquire the execute lock for Workflow <name>.
Cause:You started the specified workflow, but the Load Manager could not lock the workflow before running it. This message occurs when you or another user is currently running the workflow.
Action:Make sure that the workflow has finished running before running it again.
LM_36401<Session task instance> <task instance path> Execution terminated unexpectedly.
Cause:The DTM process did not stop, abort, or fail properly.
Action:Contact Informatica Technical Support.

LM_36440<Task type> task instance <task instance path>: Error in fetching persistent variable values for <workflow or worklet> [workflow or worklet name].
Cause:The Integration Service failed to get a persistent variable value for the workflow or worklet.
Action:Check the Integration Service log and Repository Agent log for more information.
LM_36441Error: Both parameter list and parameter file are specified.
Cause:A third party application tried to start a workflow and specified both a parameter list and a parameter file. The Integration Service needs one or the other to run a workflow, not both.
Action:In the third party application, verify you only specify a parameter list or a parameter file.
LM_36471<Workflow name>: Failover of workflow schedule failed because the information in storage is inconsistent or incomplete.
Cause:Trace message. If you have the high availability option, workflow schedule information is written to a storage file in the storage directory, $PMStorageDir. The Integration Service could not retrieve the information required to start up the scheduled workflow on another node.
Action:Explicitly schedule the workflow again to run it.

LM_36476<Workflow name>: Failover of workflow execution failed because the workflow cannot be internally scheduled in recovery mode.
Cause:After the Integration Service failed over the workflow to another node, an internal limit was exceeded.
Action:Try to recover the workflow manually. Also, verify the availability of the node where the service process started the workflow.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

SQLServerF1 Team
Information about Informatica Error Code Messages or Warning Messages on Windows and Linux Operating Systems.


Leave a Reply

Your email address will not be published. Required fields are marked *