Troubleshooting Informatica Error Messages and Resolution – Part 203

SQLServerF1

LM_36367<Task instance name and path>: Suspension email has an empty user name.
Cause:You configured the workflow to send a suspension email, but the email address for the suspension email is missing.
Action:Enter an email address in the Email User Name field for the suspension Email task.
LM_36368<Task instance name and path>: Failed to send suspension email.
Cause:You configured the workflow to send a suspension email, but the Integration Service failed to send the suspension email. This might occur if you did not specify an email profile on the machine hosting the Integration Service, or if the machine does not have an email client.
Action:Verify you specified an email profile on the machine hosting the Integration Service, and that the machine has the correct email client.

LM_36369<Session task instance> <task instance path> Encountered task instance <task instance name> of unknown type.
Cause:The Integration Service has encountered a task type that it cannot recognize because the version of the Integration Service and repository are inconsistent. You have upgraded the repository but not the Integration Service.
Action:Upgrade the Integration Service.
LM_36381<Worklet name>: Failed to set the passed value for variable <name>. Cannot find a user-defined variable with this name.
Cause:The Integration Service attempted to override the initial value of the named variable in the named worklet, but it could not locate the named worklet variable.
Action:Make sure you defined the named variable in the worklet.
LM_36382<Worklet name>: Failed to set the passed value for variable <name>. The variable <name> cannot be found at the parent <workflow or worklet name>.
Cause:The Integration Service attempted to override the initial value of the named variable in the named worklet. It could not do this because it could not locate the named parent workflow or worklet variable.
Action:Make sure you defined the named variable in the parent workflow or worklet.

LM_36383Error in expanding variable parameter.
Cause:Internal error.
Action:Contact Informatica Technical Support.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Informatica Error Code Messages or Warning Messages on Windows and Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *