EP_13264Fatal Error: It is illegal to call INFA_CTGetRowStrategy outside inputRowNotification.
Cause:The Custom transformation procedure code uses the INFA_CTGetRowStrategy() function inside a function other than the p_<proc_name>_inputRowNotification() function.
Action:Edit the procedure code and only use the INFA_CTGetRowStrategy() function inside the p_<proc_name>_inputRowNotification() function.

EP_13265Fatal Error: It is illegal to call INFA_CTGetRowStrategy when the data access mode is ARRAY.
Cause:The Custom transformation procedure code uses the INFA_CTGetRowStrategy() function when the data access mode is array-based.
Action:Edit the procedure code and use the INFA_CTAGetRowStrategy() function to get the default row strategy.
EP_13266Fatal Error: It is illegal to call INFA_CTOutputNotification outside inputRowNotification when the transformation scope is ROW.
Cause:The Custom transformation procedure code uses the INFA_CTOutputNotification() function inside a function other than the p_<proc_name>_inputRowNotification() function when the transformation scope is row.
Action:Change the transformation scope to transaction or all input.
EP_13267Fatal Error: Invalid block size is set for OutputNotification.
Cause:The Custom transformation procedure code uses the INFA_CTASetNumRowsInBlock() function to set the number of rows in a block. However, the number of rows is invalid.
Action:Edit the procedure code and verify the value for the nRows argument in the INFA_CTASetNumRowsInBlock() function is greater than 0 and less than or equal to the value returned by the INFA_CTAGetOutputRowMax() function.

EP_13268Fatal Error: It is illegal to call INFA_CTASetOutputNumRowsMax at run-time.
Cause:The Custom transformation procedure code contains the INFA_CTASetOutputNumRowMax() function in a notification function.
Action:Edit the procedure code and only use the INFA_CTASetOutputNumRowMax() function in an initialization function.
EP_13269Fatal Error: Invalid block size is being passed to INFA_CTASetOutputNumRowsMax.
Cause:The Custom transformation procedure code uses the INFA_CTASetOutputNumRowMax() function, but the nRowsMax argument is an invalid number.
Action:Edit the procedure code and verify nRowsMax is a positive number.
EP_13270Fatal Error: Downstream Transformations have encountered a fatal error. Please refer to session log.
Cause:A transformation downstream from a Custom transformation encountered a fatal error.
Action:Read the session log for other error messages.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.