Troubleshooting Informatica Error Messages and Resolution – Part 122

SQLServerF1_Header_Small

EP_13010Cannot create external module object.
Cause:The class factory function CreateExternalModuleObject failed to create an external module object in the Informatica external module.
Action:Examine the CreateExternalModuleObject function and the constructor for the external module object called within it.

EP_13011NULL external procedure name.
Cause:You did not enter the procedure name in the External Procedure transformation.
Action:Enter a valid name for the procedure.
EP_13012Cannot get external procedure signature.
Cause:A call to the TINFExternal Module Impl::GetProcSignature function failed.
Action:Examine this function in the file infemimp.cpp. Also, make sure that the INFEMProcSignatures and the p*ParamVector data structures in the module_nameEM.CPP file have not been altered.
EP_13013Number of ports in transform does not match number of formal arguments.
Cause:The Integration Service cannot match the number of ports in an External Procedure transformation with the number of formal arguments in the external procedure.
Action:Correct either the number of arguments in the external procedure or the number of ports in the External Procedure transformation before running the session again.

EP_13014Multiple return ports defined for transform.
Cause:Internal error.
Action:Contact Informatica Technical Support.
EP_13015Multiple return arguments defined for external procedure.
Same as EP_13014.

EP_13020External procedure has return value, but transform does not.
Cause:The external procedure has a return value, but the External Procedure transformation does not.
Action:Either add a return value to the External Procedure transformation or remove it from the external procedure code.
EP_13021Transform has return value, but external procedure does not.
Cause:The External Procedure transformation has a return value, but the external procedure does not.
Action:Either add a return value to the external procedure code or remove it from the External Procedure transformation.

Above are list of Informatica Error Messages or Warnings received while performing certain operation against Informatica related products.

What are Informatica Error Messages?

Informatica error codes are a set of error codes for use by all Informatica products. Every Informatica error message returned by Informatica, is self explanatory and contains the object name in cases where required.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Informatica Error Code Messages or Warning Messages on Windows and Linux Operating Systems.

 

Leave a Reply