Teradata SQL Error and Failure Codes from Error 8526 To 8535

SQLServerF1_Header_Small

8526 LOT could not perform a function because of the endpoint state
Explanation: A requested function could not be performed because of the state of the endpoint object; e.g., an object
which is opened to send data cannot be used to receive data.
Generated By: lotimpl.c
For Whom: Software developers.
Notes: These tests are made to find simple coding errors during software development and are not expected to fail in
production.
Remedy: Contact your System Representative.

8527 LOT got an unexpected return code sending a PDE message
Explanation: A PDE message transmit service returned an error.
Generated By: lotimpl.c
For Whom: Site support representative.
Notes: None.
Remedy: Contact your System Representative.

8528 LOT was passed a zero or negative length
Explanation: LotWrite expected a positive data buffer length but was passed zero or a minus value.
Generated By: lotimpl.c
For Whom: Software developers.
Notes: This test is made to find simple coding errors during software development and is not expected to fail in production.
Remedy: Contact your System Representative.

8529 LOT expected an open operation code in the record
Explanation: A call to LotOpen passed in a LotRec structure with an unexpected value for the operation code.
Generated By: lotimpl.c
For Whom: Software developers.
Notes: This test is made to find simple coding errors during software development and is not expected to fail in production.
Remedy: Contact your System Representative.

8530 LOT got an unexpected return code receiving a PDE message
Explanation: A PDE message receive service returned a code which was neither ok nor indicative of a timeout.
Generated By: lotimpl.c
For Whom: Site support representative.
Notes: None.
Remedy: Contact your System Representative.

8531 LOT got an unexpected operation code in the record
Explanation: LOT was supplied with a LotRec structure containing an unexpected value for the operation code.
Generated By: lotimpl.c
For Whom: Software developers.
Notes: The record structure was either received from the PDE message subsystem or supplied by LotRecSeg. The receive
side checks for data and stop, the sender side checks for acknowledgements and stop.
Remedy: Contact your System Representative.

8532 LOT got an unexpected return code sending a PDE record
Explanation: A PDE message send record service returned an error.
Generated By: lotimpl.c
For Whom: Site support representative.
Notes: This can occur when LotSend sends a timeout record, when LotClose sends an end-of-data with no segment, and
when LotReceive sends an acknowledgement.
Remedy: Contact your System Representative.

8533 LOT received too many segments to hold in its receive queue
Explanation: LOT detected a receive overrun condition.
Generated By: lotimpl.c
For Whom: LOT software developers.
Notes: LOT maintains a queue of segments in a receive endpoint (for buffering and message ordering); acknowledgements
are used to throttle the sender, preventing overruns. Something in this logic is not working.
Remedy: Contact your System Representative.

8534 LOT was passed a null record pointer
Explanation: LotRecSeg expected a pointer to a LotRec structure but was passed null.
Generated By: lotimpl.c
For Whom: Software developers.
Notes: This test is made to find simple coding errors during software development and is not expected to fail in production.
Remedy: Contact your System Representative.

8535 LOT was passed a record with an invalid operation code
Explanation: LotRecSeg was passed a LotRec structure which contained an invalid operation code.
Generated By: lotimpl.c
For Whom: Software developers.
Notes: None.
Remedy: Contact your System Representative.

Above are list of Teradata Errors or Failure Codes from Error 8526 To 8535 received while performing certain operation against Teradata Database or related products.

What are Teradata Database Errors?

In general, each Teradata error message contains the following information:
• The message number.
• The message text. This text is usually returned with the message number. Some messages employ word substitution, where the word substituted represents the system-replacement of a term more specific to the occurrence.
• An explanation of how the error may have occurred.
• Generated-by text that indicates the software module which initiated the message. This field serves a diagnostic purpose for support and development personnel.
• A remedy which suggests how to resolve the condition.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Teradata SQL Error and Failure Codes and Error Messages on Windows, Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *