Teradata SQL Error and Failure Codes from Error 7812 To 7824

7812 Internal error in Table operator %DBID.%TVMID, %VSTR
Explanation: This error indicates that something unexpected happened such as missing table context or table operator
context, the buffer in bad state, or buffer record in bad format, row ID check failure.
Generated By: FNC Library
For Whom: UDF application developer
Remedy: Contact your support representative.

7813 %VSTR.
Explanation: This error indicates that the direction, the state, or the mode of the parameter stream is invalid. Or, the stream has not beeen set up to access attribute values directly.
Generated By: FNC Library
For Whom: UDF application developer
Remedy: Check that the stream’s direction, state, and mode are valid for the FNC function being called. Need to open
stream with third parameter set to true to be able to call FNC_TblOpGetAttributeByNdx or NC_TblOpSetAttributeByNdx.

7814 %VSTR.
Explanation: This error indicates that the size of buffer or the number of columns or the size of column names is too
small.
Generated By: FNC Library
For Whom: UDF application developer
Remedy: Allocate more space for the buffer or column names.

7815 %VSTR.
Explanation: This error indicates that the input is invalid. For example, the index of custom argument clause or attribute
is invalid, or the attribute length does not match the attribute definition.
Generated By: FNC Library
For Whom: UDF application developer
Remedy: Check the error message and provide valid input values.

7816 %VSTR.
Explanation: This error indicates that some usage is not supported in the table operator. For instances, LOBs are not
supported with raw row mode; iterator APIs are not supported with the INDICBUFFMT1 format.
Generated By: FNC Library
For Whom: UDF application developer
Remedy: Check the error message and rewrite the table operator code.

7817 %VSTR.
Explanation: This error indicates that the format type or field format is invalid.
Generated By: FNC Library
For Whom: UDF application developer
Remedy: Verify that the values passed as format type and field format are valid.

7820 A UDF subsystem informative event was logged.
Explanation: This message is used to display informative information regarding the UDF/UDM/XSP (external routines)
subsystem concerning the the following possible issues:
1. Secure server external routine user authorization errors. 2. Unexpected Window system Desktop errors. 3. Secure server creation error. 4. UDF subsystem initialization errors. 5. Issues with external routine causing failures. 6. Any other anomalous issues with external routine execution.
The messages of this type will appear in the system log only.
Generated By: UDF subsystem.
For Whom: DBA, UDF developer
Remedy: The actions to take are numerous. Normally the contents of the message will be sufficient to indicate the action that might have to be taken. For example a message indicating that a UDF caused a trap while running in non protected mode on a PE would mean that the function in question has some serious problems and the function should be removed from the system or at least changed to run in protected mode to figure out the issues with the function.

7821 The not protected mode UDF/UDM %DBID.%TVMID caused an exception.
Explanation: This message is generated when a UDF/UDF caused an exception while executing the function when running
non protected mode on a PE.
Generated By: UDF subsystem.
For Whom: DBA, UDF developer
Remedy: The function in question needs to be fixed. The system log might contain additional information. Change the
function execution mode to run protected and rerun it with the same data that caused the problem. Add trace statements to help find the problem.

7823 GLOP Set %DBID.%TVMID has errors : %VSTR.
Explanation: Problems were encountered in establishing or using the GLOP. The text has further explanation as to what
went wrong.
Generated By: GLOP subsystem.
For Whom: UDF Developer, Database Administrator
Remedy: The solution depends on the problems encountered. In most cases it is caused by either system limitations such
a not enough system disc space or wrong system file permissions or memory issues with the system. The remedy is to
reduce the size of the GLOP set. Increase the system disk space. Increase physical memory or fix permission issues.

7824 GLOP Set Logic Internal Error: %VSTR.
Explanation: The GLOP Managment system experienced an internal logic error.
Generated By: GLOP subsystem.
For Whom: Site support representative.
Remdedy: Contact your System Representative.

Above are list of Teradata Errors or Failure Codes from Error 7812 To 7824 received while performing certain operation against Teradata Database or related products.

What are Teradata Database Errors?

In general, each Teradata error message contains the following information:
• The message number.
• The message text. This text is usually returned with the message number. Some messages employ word substitution, where the word substituted represents the system-replacement of a term more specific to the occurrence.
• An explanation of how the error may have occurred.
• Generated-by text that indicates the software module which initiated the message. This field serves a diagnostic purpose for support and development personnel.
• A remedy which suggests how to resolve the condition.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Teradata SQL Error and Failure Codes and Error Messages on Windows, Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *