Teradata SQL Error and Failure Codes from Error 6112 To 6127

6112 Host Descriptor in a configuration map is invalid.
Explanation: This error occurs if any host field is invalid.
Generated By: RCOCkFig.
For Whom: Support Representative.
Notes: The configuration table may or may not be properly initialized.
Remedy: Contact your Support Representative.

6113 AddressClass in a MsgArgs is invalid.
Explanation: This error occurs if the AddressClass of the passed MsgArgs is not valid.
Generated By: RCOGSta, RCORecon.
For Whom: Support Representative.
Notes: This is a programming error.
Remedy: Contact your Support Representative.

6114 Message Kind is invalid in the message header.
Explanation: This error occurs if the Kind field of the message header is not valid.
Generated By: RCOSHB/RCOStaHd.
For Whom: Support Representative.
Notes: This is a programming error.
Remedy: Contact your Support Representative.

6115 A specified Vproc does not exist in a specified Config Map.
Explanation: This error occurs if the specified Vproc does not exist in a specified configuration map.
Generated By: RCOParse.
For Whom: End User.
Remedy: START CONFIG to check the current configuration map. Verify the physical configuration.

6120 Restarting DBS due to completion of reconfiguration.
Explanation: This message is displayed when the reconfiguration process completes. The Teradata Database can then be
restarted.
Generated By: RCORECON.
For Whom: End User.
Notes: System should be restarted automatically.
Remedy: None.

6121 Add AMP, Delete AMP, and Move AMP are mutually exclusive.
Explanation: This error occurs when the “Add AMP”, “Del AMP”, and “Move AMP” operations are not exclusive during
a reconfiguration.
Generated By: RCORECON.
For Whom: Support Representative.
Notes: There is a bug in the configuration program.
Remedy: Contact your Support Representative.

6122 Reconfig state is invalid in the context block.
Explanation: This error occurs when the phase field in the Reconfig context is invalid.
Generated By: RCORECON.
For Whom: Support Representative.
Remedy: Contact your Support Representative.

6123 Not enough space to accommodate redistributed rows.
Explanation: This error occurs when the system doesn’t have enough space to redistribute rows around.
Generated By: RCOinput.
For Whom: Support Representative.
Notes: Check the DBSpace table to verify that there is not enough permspace on the AMPs to redistribute rows. This case
happened when system deleted amps or changed hashbucket size.
Remedy: The request reconfiguration cannot be performed due to lack of physical disk storage. Contact your Support
Representative.

6125 Stack overflow occurs when a float operation is invoked.
Explanation: This error occurs when the status returned from the float procedure is FltStackOver.
Generated By: RCOFltOp.
For Whom: Support Representative.
Remedy: Contact your Support Representative.

6126 Stack underflow occurs when a float operation is invoked.
Explanation: This error occurs when the status returned from the float procedure is FltStackUnder.
Generated By: RCOFltOP.
For Whom: Support Representative.
Remedy: Contact your Support Representative.

6127 Result from a float operation is abnormal.
Explanation: This error occurs when the status returned from the float procedure is neither FltOverflow, FltStackOv, or
FltStackUnder.
Generated By: RCOEstSp/RCOPhas42.
For Whom: Support Representative.
Remedy: Contact your Support Representative.

Above are list of Teradata Errors or Failure Codes from Error 6112 To 6127 received while performing certain operation against Teradata Database or related products.

What are Teradata Database Errors?

In general, each Teradata error message contains the following information:
• The message number.
• The message text. This text is usually returned with the message number. Some messages employ word substitution, where the word substituted represents the system-replacement of a term more specific to the occurrence.
• An explanation of how the error may have occurred.
• Generated-by text that indicates the software module which initiated the message. This field serves a diagnostic purpose for support and development personnel.
• A remedy which suggests how to resolve the condition.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Teradata SQL Error and Failure Codes and Error Messages on Windows, Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *