Teradata SQL Error and Failure Codes from Error 5881 To 5891

5881 CLOBs can only be converted to CHAR or VARCHAR.
Explanation: A CLOB data type can only be converted to a CHAR or VARCHAR data type.
Generated By: Optimizer Module.
For Whom: End User.
Remedy: None.

5882 Invalid SET statement in the triggered action.
Explanation: (a) The SET statement syntax should be: SET <column-1> = <expression-1>;
Where <column-1>, <column-2> are columns of the Subject Table on which the BEFORE row trigger is defined and
<expression-1>, <expression-2> are scalar expressions.
The SET statement can only be specified in definition of a Trigger. If it is used else where, this error message is generated.
(b) Any syntactic of semantic errors in the SET statement.
Generated By: RES, SYN modules.
For Whom: End user or Field Engineer or the concerned site support Representative
Notes: SET Statement can only be specified either in a CREATE TRIGGER or in a REPLACE TRIGGER statement.
Remedy: None.

5883 Random Amp Sampling timed out.
Explanation: A time out occured while waiting for response message from the AMPs which is posted to the event log.
Generated By: mgc modules.
For Whom: End User.
Remedy: Either the system has been very busy or there could be some problem within the system. The system switches
to default one AMP sampling and recovers from the error. If the problem persists, please contact the system support representative
with all details.

5884 Invalid Random AMP Sampling type found.
Explanation: An invalid Random AMP sampling type was found during processing which is posted in the event log.
Generated By: mgc modules.
For Whom: Database Administrator.
Remedy: The system has detected an internal error while processing. It recovers from the error by switching to default
one AMP sampling. Please contact the system support representative with all details.

5885 Invalid Random AMP Sampling express request.
Explanation: An invalid Random AMP sampling express request type was detected and is posted in the event log.
Generated By: mgc modules.
For Whom: Database Administrator.
Remedy: The system has detected an internal error while processing. It recovers from the error by switching to default
one AMP sampling. Please contact the system support representative with all details.

5886 Invalid AMP Response received.
Explanation: An invalid AMP response was received during random amp sampling and is posted in the event log.
Generated By: mgc modules.
For Whom: Database Administrator.
Remedy: The system has detected an internal error while processing It recovers from the error by switching to default
one AMP sampling. Please contact the system support representative with all details.

5887 Internal error encountered in random amp sampling.
Explanation: An internal error was encountered during random amp sampling.
Generated By: mgc modules.
For Whom: Database Administrator.
Remedy: The system has detected an internal error while processing It recovers from the error by switching to default
one AMP sampling. Please contact the system support representative with all details.

5888 Switching to default one amp sampling.
Explanation: The system is switching from a multiple AMP sampling mode to single AMP sampling mode due to some
internal error in the system.
Generated By: mgc modules.
For Whom: Database Administrator.
Remedy: This is an informative message. If this persists,please contact your system support representative with all the
details.

5889 Problem encountered while sending messages to multiple AMPs during multi amp sampling.
Explanation: The system enccountered an error while sending message to multiple AMPs during multiple AMP sampling.
Generated By: mgc modules.
For Whom: Database Administrator.
Remedy: The system automatically switches to default one AMP sampling. Please contact your system support representative with all the details.

5890 An invalid user-defined QITS column was defined.
Explanation: The user-defined QITS must be the first column of the CREATE TABLE syntax and be defined with the
attributes: TIMESTAMP(6) NOT NULL DEFAULT CURRENT_TIMESTAMP(6).
Generated By: RES modules.
For Whom: End User.
Remedy: Omit those options and resubmit statement.

5891 An invalid queue table creation or alter was supplied.
Explanation: The CREATE TABLE or ALTER TABLE statement contains an option, or specification, that is not valid for
queue tables. The following variations are not allowed for queue tables: – Dropping the QITS column, – LOB data type column,
– Lob UDT data type column, – GLOBAL TEMPORARY clause, – VOLATILE clause, – UNIQUE, or PRIMARY KEY,
clause for the QITS column, – SET is specified or defaulted and the QITS is the only column, – PARTITION BY clause, –
BEFORE/AFTER JOURNAL clause, – or the AS clause, – Changing the NOT NULL attribute of the QITS column, – Changing
the DEFAULT attribute of the QITS column.
Generated By: Syntaxer modules.
For Whom: End User.
Remedy: Remove the invalid option from the CREATE TABLE or ALTER TABLE statement

Above are list of Teradata Errors or Failure Codes from Error 5881 To 5891 received while performing certain operation against Teradata Database or related products.

What are Teradata Database Errors?

In general, each Teradata error message contains the following information:
• The message number.
• The message text. This text is usually returned with the message number. Some messages employ word substitution, where the word substituted represents the system-replacement of a term more specific to the occurrence.
• An explanation of how the error may have occurred.
• Generated-by text that indicates the software module which initiated the message. This field serves a diagnostic purpose for support and development personnel.
• A remedy which suggests how to resolve the condition.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Teradata SQL Error and Failure Codes and Error Messages on Windows, Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *