5218 Some number of WDBs at the end of the log were lost.
Explanation: The last known appended WAL log record was not found in the reconstructed WAL log during startup.
Generated By: File System
For Whom: Field Engineer
Notes: This indicates a Hardware or File System software error.
Remedy: Contact a field engineer.

5219 Cylmigrate ran out of cylinders trying to find a CI it could return to cylpack.
Explanation: A MINICYLPACKOUT operation was unable to obtain a write lock on a CI while walking backwards up
the MI before running out of CIs.
Generated By: File System
For Whom: Field Engineer
Notes: This error code is only used to pass information between internal file system functions.
Remedy: Contact a field engineer.

5221 Cylmigrate freed a CI to the WABC rather than the free cylinder pool.
Explanation: During a MINICYLPACKOUT operation, a cylinder was freed and placed in the WABC freecyl array
rather than into the free cylinder pool.
Generated By: File System
For Whom: Field Engineer
Notes: This error code is only used to pass information between internal file system functions.
Remedy: Contact a field engineer.

5222 ………………………………………………………..
Detected interrupted write pattern on the FIB: %s Alternate copy chosen
………………………………………………………..
Explanation: An interrupted write pattern was found in the FIB. This pattern is placed there by disk array vendors when
a requested write could not be completed. The alternate copy of the FIB was automatically chosen. No further action is
required.
Generated By: File System
For Whom: Field Engineer
Notes: This indicates that an interrupted write occured at some time in the past and is being detected on a read operation.
Remedy: No action required.

5223 ………………………………………………………..
Detected interrupted write pattern on the CI: %s Alternate copy chosen………………………………………………………..
Explanation: An interrupted write pattern was found in the CI. This pattern is placed there by disk array vendors when
a requested write could not be completed. The alternate copy of the CI was automatically chosen. No further action is
required.
Generated By: File System
For Whom: Field Engineer
Notes: This indicates that an interrupted write occured at some time in the past and is being detected on a read operation.
Remedy: No action required.

5224 …………………………………………. Detected interrupted write pattern on both copies of Seg0, the FIB, or CI: %s Neither copy could be chosen ……………………………………………
Explanation: An interrupted write pattern was found in both copies of seg0, the FIB, or CI. This pattern is placed there
by disk array vendors vendors when a requested write could not be completed. Neither copy of segment0, the FIB, or CI is
valid.
Generated By: File System
For Whom: Field Engineer
Notes: This indicates that an interrupted write occurred at some time in the past and is being detected on a read operation.
If both copies of the FIB or CI are bad, multiple interrupted writes occurred and the device has suffered a serious failure.
Remedy: Contact a field engineer.

5225 The WDBD and WDB TJ record counts do not match.
Explanation: The TJ record count in the WDB does not match the TJ record count in the WDBD.
Generated By: File System
For Whom: Field Engineer
Notes: This indicates either a File System software error or a Hardware error has occurred.
Remedy: Contact a field engineer.

5226 An out of order WAL append buffer has been detected.
Explanation: The WLSN of the first record in the WAL append buffer being processed by the WAL writer task is not in
proper WLSN order for the append operation.
Generated By: File System
For Whom: Field Engineer
Notes: This indicates either a File System software error or a Hardware error has occurred.
Remedy: Contact a field engineer.

Above are list of Teradata Errors or Failure Codes from Error 5218 To 5226 received while performing certain operation against Teradata Database or related products.

What are Teradata Database Errors?

In general, each Teradata error message contains the following information:
• The message number.
• The message text. This text is usually returned with the message number. Some messages employ word substitution, where the word substituted represents the system-replacement of a term more specific to the occurrence.
• An explanation of how the error may have occurred.
• Generated-by text that indicates the software module which initiated the message. This field serves a diagnostic purpose for support and development personnel.
• A remedy which suggests how to resolve the condition.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Teradata SQL Error and Failure Codes and Error Messages on Windows, Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *