Teradata SQL Error and Failure Codes from Error 3823 To 3834

3823 VIEW ’%VSTR’ may not be used for Help Index/Constraint/Statistics, Update, Delete or Insert.
Explanation: The view specified can only be used for retrievals. The user cannot use this view for INSERT, UPDATE, or
DELETE statements, nor can the user ask for index/statictics/constraint information on a view that is not on a single table.
Generated By: RES modules.
For Whom: End User.
Notes: A view that contains any expressions, joins, or aggregates cannot be used for manipulating the data in the underlying
table. The HELP INDEX, HELP STATISTICS, HELP CONSTRAINT statements will also not work on such views.
Remedy: Redefine the view or do not use a view.

3824 Macro ’%VSTR’ does not exist.
Explanation: The macro specified does not exist in the specified database(s).
Generated By: RES and OPT modules.
For Whom: End User.
Remedy: Check the spelling of the macro name; make sure that the correct database is specified.

3825 Incomplete table.
Explanation: A failed restore probably left a DBC table incomplete. An attempt was made to access the incomplete table
using a secondary index but nothing was found where there was supposed to be something. At the moment, a bad restore
is the only thing known to cause this error.
Generated By: RES modules.
For Whom: End User.
Remedy: Do a good restore .

3826 A 2PC parcel is only valid when in a 2PC session.
Explanation: A user issued a 2PC parcel while not in 2PC mode. A session must be logged on as a 2PC session.
Generated By: ParDrivr.
For Whom: End User.
Remedy: Logon a 2PC session and retry the request(s).

3827 A 2PC Vote, Commit, or Vote & Terminate was received while in an inner transaction.
Explanation: A user issued a 2PC parcel while in an inner transaction. VOTE, COMMIT and VOTE/TERMINATE
requests are only valid when no user generated transaction exists.
Generated By: ParDrivr and GncApply.
For Whom: End User.
Remedy: Re-execute the requests with properly matched BEGIN and END TRANSACTION statements.

3828 A commit is valid for in-doubt transactions only.
Explanation: A user issued a commit for a transaction that was not in-doubt. An in-doubt transaction results from a
VOTE request. This failure caused the transaction to be rolled back.
Generated By: ParDrivr.
For Whom: End User.
Remedy: Re-execute all the requests, except the commit, then issue a vote followed by a commit.

3829 DDL is not allowed in a 2PC session.
Explanation: Data Definition Language statements are not allowed in 2PC sessions.
Generated By: Resolver.
For Whom: End User.
Remedy: Execute the request without DDL statements.

3831 A 2PC parcel must be in a 2PC transaction.
Explanation: A 2PC parcel was received before the Parser received an SQL request.
Generated By: ParDrivr.
For Whom: End User.
Remedy: Issue the 2PC parcel after executing an SQL request.

3832 A 2PC parcel must not directly follow an Options parcel.
Explanation: A 2PC parcel was sent after an Options parcel. Options parcels must be followed by a non-2PC parcel.
Generated By: ParDrivr.
For Whom: End User.
Remedy: Parcels must be issued in proper sequence.

3833 A CHECKPOINT statement is not allowed in a 2PC session.
Explanation: CHECKPOINTS are not allowed in 2PC.
Generated By: Resolver.
For Whom: End User.
Remedy: Resubmit the request without using a CHECKPOINT statement.

3834 The session has an in-doubt transaction, which must be resolved before new requests can be submitted.
Explanation: This error is issued following a DBS reset when the session has an in-doubt transaction and the user or
application submitted a new request.
The transaction may be in-doubt because it updates a replicated table. Normally, such a transaction is eventually resolved automatically, but resolution may be delayed if the replication transport provider does not respond quickly enough.
Generated By: ParDrivr.
For Whom: End User.
Remedy: The application can proceed once the in-doubt transaction has been resolved. It may have to re-execute the indoubt transaction or use some other technique to determine its outcome before proceeding on to new work.

Above are list of Teradata Errors or Failure Codes from Error 3823 To 3834 received while performing certain operation against Teradata Database or related products.

What are Teradata Database Errors?

In general, each Teradata error message contains the following information:
• The message number.
• The message text. This text is usually returned with the message number. Some messages employ word substitution, where the word substituted represents the system-replacement of a term more specific to the occurrence.
• An explanation of how the error may have occurred.
• Generated-by text that indicates the software module which initiated the message. This field serves a diagnostic purpose for support and development personnel.
• A remedy which suggests how to resolve the condition.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Teradata SQL Error and Failure Codes and Error Messages on Windows, Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *