Teradata SQL Error and Failure Codes from Error 2624 To 2632

SQLServerF1_Header_Small

2624 Internal error: no format given for editing
Explanation: This error indicates that an illegal sequence of Op Codes has been executed.
Generated By: The interpretative instruction processor.
For Whom: Site support representative.
Notes: This error occurs either on a DeEditOp or a EditOp, when the format given happens to be a null string.
Remedy: Contact your Support Representative.

2625 Internal error: nested open parcel operations
Explanation: This error indicates that an illegal sequence of Op Codes has been executed.
Generated By: The interpretative instruction processor.
For Whom: Site support representative.
Notes: Two open parcel ops occurred without a close parcel op between them.
Remedy: Contact your Support Representative.

2626 Internal error: parcel closed prior to open
Explanation: This error indicates that an illegal sequence of Op Codes has been executed.
Generated By: The interpretative instruction processor.
For Whom: Site support representative.
Notes: The Pseudo Machine was instructed to terminate a parcel that was not opened.
Remedy: Contact your Support Representative.

2627 Internal error: invalid operand for UpCaseOp
Explanation: This error indicates that an illegal sequence of Op Codes has been executed.
Generated By: The interpretative instruction processor.
For Whom: Site support representative.
Notes: This error occurs if, for instance, an UpCaseOp is performed on YnetAsc or YnetDesc format data.
Remedy: Contact your Support Representative.

2628 Internal error: creating fields out of order.
Explanation: This error indicates that an illegal sequence of Op Codes has been executed.
Generated By: The interpretative instruction processor.
For Whom: Site support representative.
Notes: For example, the user was told to put field 1009 before field 1007, but did not.
Remedy: Contact your Support Representative

2629 Internal error: bad data type for operation.
Explanation: This error indicates that an illegal sequence of Op Codes has been executed.
Generated By: The interpretative instruction processor.
For Whom: Site support representative.
Notes: This error occurs when an operation is requested that does not make sense (for example, comparing numbers to
characters, adding character or byte strings, etc.).
Remedy: Contact your Support Representative.

2630 Internal error: null lower set bound
Explanation: This error indicates that an illegal sequence of Op Codes has been executed.
Generated By: The interpretative instruction processor.
For Whom: Site support representative.
Notes: This error occurs when a Set Check operation is performed and the field checked first is Null or not there.
Remedy: Contact your Support Representative.

2631 Transaction ABORTed due to %VSTR.
Explanation: This error indicates that:
(1) an excessive number of transactions were queued waiting for locks, and the user’s request would have blocked on the
lock queue, or
(2) the request conflicted with another request, causing a deadlock, or
(3) a software problem (for example, a lost message) occurred, causing the request to “time out”.
(4) a dirty read error occurred due to conurrent update from a separate thread, causing the request to be aborted.
Generated By: AMP Software.
For Whom: End User.
Remedy: Resubmit the transaction.

2632 All AMPs own sessions for this Fast/Multi Load or FastExport.
Explanation: This error occurs when all AMPs have a session assigned to them for the ongoing FastLoad, MLoad or
FastExport.
Generated By: AMP Software.
For Whom: Internal Message Only.
Notes: This error exists only to instruct the utility program to stop attempting to log sessions onto the Teradata DBS.
Remedy: None possible.

Above are list of Teradata Errors or Failure Codes from Error 2624 To 2632 received while performing certain operation against Teradata Database or related products.

What are Teradata Database Errors?

In general, each Teradata error message contains the following information:
• The message number.
• The message text. This text is usually returned with the message number. Some messages employ word substitution, where the word substituted represents the system-replacement of a term more specific to the occurrence.
• An explanation of how the error may have occurred.
• Generated-by text that indicates the software module which initiated the message. This field serves a diagnostic purpose for support and development personnel.
• A remedy which suggests how to resolve the condition.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Teradata SQL Error and Failure Codes and Error Messages on Windows, Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *