Teradata SQL Error and Failure Codes from Error 16036 to 16047

SQLServerF1

16036 Call to SamAllocatorInit failed.
Explanation: Unable to process SamAllocatorInit request.
Generated By: TVS SAM Library
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

16037 A message was sent before the TVS Vproc was ready to process it.
Explanation: The TVS Vproc was still initializing when it received a message.
Generated By: TVS SAM Library
For Whom: Field Engineer
Remedy: Wait a short time and retry the operation.

16038 Call to SamFinishQuarantineRecovery failed.
Explanation: Call to SamFinishQuarantineRecovery failed.
Generated By: TVS SAM Library
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

16039 Call to SamGetQuarantineList failed.
Explanation: Call to SamGetQuarantineList failed.
Generated By: TVS SAM Library
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

16040 The caller’s VPROCID does not match the cylinder’s owner.
Explanation: The caller is not the owner of the requested cylinderid.
Generated By: TVS SAM Library
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

16041 Call to SamUnSequesterAll failed.
Explanation: Call to SamUnSequesterAll failed.
Generated By: TVS SAM Library
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

16042 Some pdisks or TVS Vprocs are inaccessible. The calling AMP may be missing data.
Explanation: The system has one or more inaccessible pdisks or one or more TVS vprocs are FATAL. The calling AMP
may have had data on the affected pdisk(s) or cylinders managed by the affected TVS vproc(s).
Generated By: TVS SAM Library
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

16043 SamReleaseExtentList was called after cylinders in the list had been modified.
Explanation: Internal error. SamReleaseExtentList should not be called if any of the cylinders in the list have been modified
or released.
Generated By: TVS SAM Library
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

16044 Requested TVS Vproc is fatal
Explanation: This SAMLIB call requires access to a TVS Vproc.
Generated By: TVS SAM Library
For Whom: Field Engineer
Remedy: Determine why the TVS Vproc is fatal, remedy that problem, then use vprocmanager to bring the TVS Vproc
back online before attempting this operation again.

16045 The SAM request failed due to a device I/O failure.
Explanation: The allocator could not complete the request due to an I/O failure. See event messages logged by the TVS
Allocator for details.
Generated By: TVS SAM Library
For Whom: Field Engineer
Remedy: Determine which device is having problems and repair the device.

16046 An AMP that is not in the configuration tried to connect.
Explanation: An AMP that is not currently in the vconfig.gdo attempted to connect to TVS.
Generated By: TVS SAM Library
For Whom: Field Engineer
Remedy: If a delete AMP procedure is in progress, do not try to start the database until the delete AMP procedure has
been completed. Check vconfig for improper configuration.

16047 The system is being restarted to bring FATAL TVS vprocs online for sysinit.
Explanation: The user tried to sysinit but one or more TVS vprocs were FATAL or OFFLINE. They have been set online
but a restart is required to bring them into the system.
Generated By: TVS SAM Library
For Whom: Field Engineer
Remedy: This is an intentional restart. Sysinit should be executed again following the restart.

Above are list of Teradata Errors or Failure Codes from Error 16036 to 16047 received while performing certain operation against Teradata Database or related products.

What are Teradata Database Errors?

In general, each Teradata error message contains the following information:
• The message number.
• The message text. This text is usually returned with the message number. Some messages employ word substitution, where the word substituted represents the system-replacement of a term more specific to the occurrence.
• An explanation of how the error may have occurred.
• Generated-by text that indicates the software module which initiated the message. This field serves a diagnostic purpose for support and development personnel.
• A remedy which suggests how to resolve the condition.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Teradata SQL Error and Failure Codes and Error Messages on Windows, Linux Operating Systems.

 

Leave a Reply