Teradata SQL Error and Failure Codes from Error 15015 to 15025

SQLServerF1

15015 The TVS Extent Driver returned an error on a stat ring map request: %s
Explanation: The TVS Node Agent issued the command to the Extent Driver to map the I/O statistics ring buffer into
user memory, and this command failed. This could be due to a missing, corrupt, or outdated Extent Driver or to an internal
TVS error.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

15016 Bad token on line %d of the TVS Node Agent configuration file.
Explanation: Certain TVS Node Agent runtime parameters may be configured by setting values in the TVS Node Agent
configuration file. When scanning this file, the Node Agent has detected a parameter it does not understand. The offending
line was ignored. Any subsequent errors seen in the file will not be reported.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: Edit the configuration file and fix the offending line.

15017 Bad value on line %d of the TVS Node Agent configuration file.
Explanation: Certain TVS Node Agent runtime parameters may be configured by setting values in the TVS Node Agent
configuration file. When scanning this file, the Node Agent has detected a parameter whose value is outside the allowable
range for this parameter.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: Edit the configuration file and fix the offending line.

15018 Too many values for parameter at line %d of the TVS Node Agent configuration file.
Explanation: Certain TVS Node Agent runtime parameters may be configured by setting values in the TVS Node Agent
configuration file. When scanning this file, the Node Agent has detected that too many values for the parameter were specified.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: Edit the configuration file and remove some lines containing this parameter.

15019 The TVS Node Agent received an unexpected message of type %d during startup.
Explanation: The TVS Node Agent received a message of an unexpected type. This event will prevent TVS startup from
completing normally, so a reset will be performed.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

15020 The TVS Node Agent was invoked improperly.
Explanation: The TVS Node Agent was invoked with an invalid argument list. Because this invocation is internal to the
TVS subsystem, a reset will be performed.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

15021 The TVS Node Agent received an ioctl failure from the TVS device: %s
Explanation: The TVS Node Agent performed an ioctl call to the TVS device and the call failed. This indicates that the
TVS device driver is loaded but may not match the current TVS Node Agent code, or that either the TVS Node Agent or the
TVS Driver is malfunctioning. TVS cannot continue until this problem is resolved.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

15022 AMP vproc %d does not have a valid TVS vproc assignment.
Explanation: The AMP vproc entry shown contains a TVS vproc number that either does not exist in the vconfig or is
not of the proper vproc type.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: Repair the vconfig.

15023 AMP vproc %d and TVS vproc %d belong to different subpools.
Explanation: The AMP vproc entry shown is assigned to the TVS vproc shown, but these two vprocs are placed into two
different subpools. This is illegal because the given AMP will be unable to allocate any storage.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: Repair the vconfig.

15024 Vproc %d in clique %d is assigned subpool %d which is already in use in clique %d.
Explanation: Subpool numbers must be unique across the system. Any particular clique must not share subpools with
any other clique. This applies to both AMP and TVS vprocs.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: Repair the vconfig.

15025 The TVS Node Agent got error %d when initializing RSS data collection
Explanation: The TVS Node Agent was unable to initialize the RSS data collection subsystem. RSS statistics maintained
by the TVS Node Agent will not be updated in the collection buffers or database tables.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

Above are list of Teradata Errors or Failure Codes from Error 15015 to 15025 received while performing certain operation against Teradata Database or related products.

What are Teradata Database Errors?

In general, each Teradata error message contains the following information:
• The message number.
• The message text. This text is usually returned with the message number. Some messages employ word substitution, where the word substituted represents the system-replacement of a term more specific to the occurrence.
• An explanation of how the error may have occurred.
• Generated-by text that indicates the software module which initiated the message. This field serves a diagnostic purpose for support and development personnel.
• A remedy which suggests how to resolve the condition.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Teradata SQL Error and Failure Codes and Error Messages on Windows, Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *