Teradata SQL Error and Failure Codes from Error 14096 to 15004

SQLServerF1

14096 %$HeaderInformational Message: %s
Explanation: This is to print to /var/log/messages without restarting.
Generated By: TVS Unresponsive Node
For Whom: Field Engineer
Remedy: N/A Informational only

14097 %$HeaderWarning Message: %s
Explanation: A non fatal issue occurred with the unresponsive node isolation software
Generated By: TVS Unresponsive Node
For Whom: Field Engineer
Remedy: This message indicates a possible issue that may need to be resolved.

14500 %$Header Exception occurred within Migrator.%s
Explanation: An exception occurred with the Migrator. The specific exception thrown and description are included in
the event info. A detailed explanation can be found in the log file.
Generated By: TVS Migrator
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

14501 %$Header A severe error occurred within Migrator that could not be responded to with exception.%s
Explanation: A severe error was detected within the Migrator. These errors are as severe, if not more so, than an ERRMIGRATOREXCEPTION.
Normally, an exception is thrown but, in these particular cases, doing so has the potential to leave
the Migrator in an unstable state. For instance, throwing exceptions within destructors forces a process to abort abnormally.
Generated By: TVS Migrator
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

15000 Error injected deliberately by the TVS Node Agent.
Explanation: This error is only used for debugging and testing certain error logging paths. It should not normally be
seen. It should be seen if the TVS Node Agent is configured to inject faults for test purposes.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

15001 A memory allocation failed in the TVS Node Agent.
Explanation: The TVS Node Agent requested memory from the system and the request could not be fulfilled. This error
indicates that the node has run out of swap space or that the software is malfunctioning. In either case, it is impossible for
the TVS Node Agent to continue.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

15002 An internal consistency check has failed in the TVS Node Agent.
Explanation: The TVS Node Agent has encountered a combination of internal states that it cannot handle. This error
indicates that the TVS Node Agent software is malfunctioning and cannot continue.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

15003 AMP Vproc %d has been marked FATAL due to an I/O error.
Explanation: The TVS Node Agent has marked the indicated AMP fatal because of a failed device which would potentially
need to be accessed by that AMP. This determination is made because the AMP belongs to the same TVS allocation
subpool as the failed device. The cause of this device problem must be remedied and a system restart performed before the AMP may be brought back online. Please check other events to get all AMP Vprocs, which are marked FATAL.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: The failed device will be shown in a previous event log. Fix the problem that caused the device failure event,
then use vprocmanager to bring the fatal AMP back online.

15004 The TVS Node Agent received error %d when creating a lock.
Explanation: The TVS Node Agent detected a failure when attempting to create a software lock. Because the lock is necessary for correct operation of the TVS Node Agent, it cannot continue.
Generated By: TVS Node Agent
For Whom: Field Engineer
Remedy: Contact the Global Support Center.

Above are list of Teradata Errors or Failure Codes from Error 14096 to 15004 received while performing certain operation against Teradata Database or related products.

What are Teradata Database Errors?

In general, each Teradata error message contains the following information:
• The message number.
• The message text. This text is usually returned with the message number. Some messages employ word substitution, where the word substituted represents the system-replacement of a term more specific to the occurrence.
• An explanation of how the error may have occurred.
• Generated-by text that indicates the software module which initiated the message. This field serves a diagnostic purpose for support and development personnel.
• A remedy which suggests how to resolve the condition.

Hope this was helpful.

Thanks,
SQLServerF1 Team
Information about Teradata SQL Error and Failure Codes and Error Messages on Windows, Linux Operating Systems.

 

Leave a Reply

Your email address will not be published. Required fields are marked *