Symantec NetBackup product is a backup and recovery product designed for enterprise users. Symantec NetBackup tool can be used to perform backups of SQL Server databases, Oracle, MySQL, Sybase, PostGres Databases, flat file backups, etc, and provides various other features. Robotic daemons or processes issue these status codes. They are also issued by programs that call the robotic operations, such as the vmchange command and
the media and device management user interfaces.

Below are some of the NetBackup Robotic status code 232 to status code 235 which may be received while using the Symantec NetBackup tool.

Robotic status code 232
Message: Volume not found in library
Explanation: The requested media was not found in the robotic library. The media
has been ejected or become inaccessible for some other reason.
¦ Examine command output, debug logs, and system logs for a more detailed
message on the error.
See “Setting debug logging to a higher level” in the Troubleshooting Guide.
¦ Issue a robot inventory Contents report to obtain the list of media in the robotic
library. See whether inventory filters have been enabled in the Media Manager
configuration file. Inventory filters affect the contents of the media list
returned from the robotic daemon or process. Use a robot test utility or an
operating system/vendor administrative interface to verify the status of media,
as needed. Update the volume configuration and search for the media if it was
not in the robotic library, as needed, and resubmit the request.

Robotic status code 233
Message: Volume is in library, but not in drive domain
Explanation: The media was in the robotic library, in a library domain that is
inaccessible to the drives that are configured in the robot.
RecommendedAction: Issue a robot inventory Contents report to obtain the list
of media in the robotic library. Check the device configuration and ensure that
the drive addresses correspond to the correct domain for the media. Correct the
device configuration as needed and restart ltid (the device daemon on UNIX and
Linux or NetBackup Device Manager service on Windows). Use a robot test utility
or a vendor administrative interface to verify the status of media, as needed.
Update the volume configuration and physically move the media into the robotic
library, as needed, and resubmit the request.

Robotic status code 234
Message: Robot denied access to the resource
Explanation: The media was found in the robotic library, but is denied access
according to an established security policy.
RecommendedAction: Issue a robot inventory Contents report to obtain the list
of media in the robotic library. Use a vendor administrative interface to verify
the status of media, as needed. Delete the media in the volume configuration, or
make the volume accessible through a vendor administrative interface, as
appropriate. Update the volume configuration, as needed, and resubmit the request.

Robotic status code 235
Message: barcode label is unreadable
Explanation: The media was found in the robotic library, but it has an unreadable
barcode label.
Recommended Action: Use the robot test utility or a vendor administrative
interface to verify the status of media. Correct the label or replace the media as
appropriate. Update the volume configuration, as needed, and resubmit the request.

Hope this was helpful.