Symantec NetBackup Device configuration status code 81 to status code 85

SQLServerF1

Symantec NetBackup product is a backup and recovery product designed for enterprise users. Symantec NetBackup tool can be used to perform backups of SQL Server databases, Oracle, MySQL, Sybase, PostGres Databases, flat file backups, etc, and provides various other features. Device configuration status codes appear in exit status and command output for the tpconfig and the tpautoconf commands, and in system or debug logs. Programs that call tpconfig and tpautoconf, such as media and device management user interfaces and the vmoprcmd command, also present these codes.

Below are some of the NetBackup Device configuration status code 81 to status code 85 which may be received while using the Symantec NetBackup tool.

Device configuration status code 81
Message: This is a drive path operation, use the -drpath option
Explanation: Apath operation was specified with the tpconfig command without
the -drpath option. This error can occur when you try to change a drive’s path
using tpconfig -update -drive.
¦ Examine command output, debug logs, and system logs for a more detailed
message on the error.
See “Setting debug logging to a higher level” in the Troubleshooting Guide.
¦ Check tpconfig usage to ensure that the command is used properly and use
tpconfig -update -drpath instead.

Device configuration status code 82
Message: Add Drive Name Rule request failed
Explanation: A request to add a drive name rule failed.
¦ Examine command output, debug logs, and system logs for a more detailed
message on the error.
See “Setting debug logging to a higher level” in the Troubleshooting Guide.
¦ The rule being added already exists.
¦ The specified host does not exist in the EMM database. Use the nbemmcmd
-addhost command to add the host to the EMM database.

Device configuration status code 83
Message: Update Drive Name Rule request failed
Explanation: An update to a drive name rule failed.
¦ Examine command output, debug logs, and system logs for a more detailed
message on the error.
See “Setting debug logging to a higher level” in the Troubleshooting Guide.
¦ The rule being updated does not exist. Ensure that the drive name rule is
entered correctly.
¦ The specified host does not have a local drive name rule configured. Configure
a drive name rule.

Device configuration status code 84
Message: Delete Drive Name Rule request failed
Explanation: Arequest to delete a drive name rule failed. You cannot add or delete
a global drive name rule.
¦ Examine command output, debug logs, and system logs for a more detailed
message on the error.
¦ A local drive name rule does not exist on the hosts specified.

Device configuration status code 85
Message: List Drive Name Rule request failed
Explanation: Could not list the drive name rules for a given host or set of hosts.
¦ Examine command output, debug logs, and system logs for a more detailed
message on the error.
See “Setting debug logging to a higher level” in the Troubleshooting Guide.
¦ Verify that the hosts are known in the EMM database.

Hope this was helpful.

Thanks,
SQLServerF1 Team