Symantec NetBackup Device configuration status code 76 to status code 79

SQLServerF1

Symantec NetBackup product is a backup and recovery product designed for enterprise users. Symantec NetBackup tool can be used to perform backups of SQL Server databases, Oracle, MySQL, Sybase, PostGres Databases, flat file backups, etc, and provides various other features. Device configuration status codes appear in exit status and command output for the tpconfig and the tpautoconf commands, and in system or debug logs. Programs that call tpconfig and tpautoconf, such as media and device management user interfaces and the vmoprcmd command, also present these codes.

Below are some of the NetBackup Device configuration status code 76 to status code 79 which may be received while using the Symantec NetBackup tool.

Device configuration status code 76
Message: NDMP config_get_connection_type failed
Explanation: The NAS host fails to successfully process the
config_get_connection_type protocol request.
Recommended Action: Examine command output, debug logs, and system logs
for a more detailed message on the error.
See “Setting debug logging to a higher level” in the Troubleshooting Guide.

Device configuration status code 77
Message: Unable to connect to the EMM server
Explanation: A request was made to the EMM server, but it either did not reach
the EMM server or resulted from a communication failure.
¦ Examine command output, debug logs, and system logs for a more detailed
message on the error.
See “Setting debug logging to a higher level” in the Troubleshooting Guide.
¦ Verify that pbx_exchange and nbemm are running.
¦ Run the tpconfig -d or vmquery -a command to verify that the EMM server
is actively running and that it accepts new connections.

Device configuration status code 78
Message: The EMM server failed to process the request
Explanation: A request was made to the EMM server, but it either did not reach
the EMM server or resulted from a communication failure.
¦ Examine command output, debug logs, and system logs for a more detailed
message on the error.
See “Setting debug logging to a higher level” in the Troubleshooting Guide.
¦ Verify that pbx_exchange and nbemm are running.
¦ Run the tpconfig -d or vmquery -a command to verify that the EMM server
is actively running and that it accepts new connections.

Device configuration status code 79
Message: Unable to allocate memory for this process
Explanation: A memory allocation request failed.
¦ Examine command output, debug logs, and system logs for a more detailed
message on the error.
See “Setting debug logging to a higher level” in the Troubleshooting Guide.
¦ Verify that adequate memory is available.

Hope this was helpful.

Thanks,
SQLServerF1 Team
In-Depth Blogs on SQL Server, Information about NetBackup Device configuration status code for SQL Server, Oracle, MySQL, Sybase, Postgres, etc on Windows and Linux Operating Systems.

 

Leave a Reply